Electrochemical Determination of Cyclopenthiazide using a Glassy Carbon Electrode by Cyclic Voltammetry
‡ Chemistry Department, Faculty of Science, University of Kufa, Iraq *e-mail: Saadomranalbade@gmail.com
Анотація
In this study, the electrochemical behavior of cyclopenthiazide was investigated at a glassy carbon electrode using cyclic voltammetry (CV). The oxidation of cyclopenthiazide was found to be completely irreversible over the scan rate range of 0.001–0.05 V s−1 and was controlled by diffusion. An irreversible oxidation peak was observed at approximately −0.889 V. Experimental parameters that affect the voltammetric response were optimized to achieve optimal analytical performance. Under the optimized conditions, the oxidation peak current showed a linear relationship with cyclopenthiazide concentration over the range of 20–200 μg mL−1. The limits of detection (LOD) and quantification (LOQ) were calculated to be 7.276 and 22.05 μg mL−1, respectively. The proposed method was successfully applied to the determination of cyclopenthiazide in pharmaceutical formulations. The developed electrochemical method is simple, rapid, cost-effective, and requires no complicated sample preparation, while providing satisfactory precision and accuracy.
Як цитувати
Saad Imran Al-Abadi, Muthana Saleh Mashkour. Electrochemical Determination of Cyclopenthiazide using a Glassy Carbon Electrode by Cyclic Voltammetry. Methods Objects Chem. Anal. 2026, 21(1), 48-52. https://doi.org/10.17721/moca.2026.48-52