ISSN 2413-6166 (Online) · ISSN 1991-0290 (Print) · DOI prefix 10.17721/moca
УкрEn
Відкритий доступ · CC BY 4.0

Innovative Design and Fabrication of Monolithic Columns Inside Microchip Devices for Determination of Ni(II) Ions

Salam Mohammed Nasser, Ahmed Ali Alkarimi, and Dakhil Nassir Tah
Nassir Tah‡
† Department of Chemistry, College of Science, University of Babylon, Babylon, 51001 Iraq;
‡ Al-Mustaqbal University, Babylon, 51001, Iraq *e-mail: sci.ahmed.ali@uobabylon.edu.iq

Анотація

An innovative system was developed by fabricating a polymer-based monolith as an effective cation-exchange column within a glass microchip, achieved through in situ polymerization of glycidyl methacrylate (GMA), acrylic acid (AAc), and acrylamide (AAm) via free radical polymerization. Epoxy rings on the monolith surface were subsequently sulfonated with Na2SO3 at 70°C to form (R-SO3Na) groups. The microchip was integrated with a modified HPLC system equipped with a 3-way sub-valve (25 μL), allowing for the reagent-injection of the imidazole-azo ligand MPDADPI to react with Ni(II) ions and form a colored complex at 513 nm within 30 seconds. The calibration curve followed Beer’s law over the range of 0.001–3.5 μg mL-¹ (R² = 0.9977). Limits of detection (LOD) and quantification (LOQ) were 0.87 and 2.87 ng mL-¹, respectively. The method was validated using atomic absorption spectrophotometry (AAS).An innovative system was developed by fabricating a polymer-based monolith as an effective cation-exchange column within a glass microchip, achieved through in situ polymerization of glycidyl methacrylate (GMA), acrylic acid (AAc), and acrylamide (AAm) via free radical polymerization. Epoxy rings on the monolith surface were subsequently sulfonated with Na2SO3 at 70°C to form (R-SO3Na) groups. The microchip was integrated with a modified HPLC system equipped with a 3-way sub-valve (25 μL), allowing for the reagent-injection of the imidazole-azo ligand MPDADPI to react with Ni(II) ions and form a colored complex at 513 nm within 30 seconds. The calibration curve followed Beer’s law over the range of 0.001–3.5 μg mL-¹ (R² = 0.9977). Limits of detection (LOD) and quantification (LOQ) were 0.87 and 2.87 ng mL-¹, respectively. The method was validated using atomic absorption spectrophotometry (AAS).

Ключові слова:monolithin-situ polymerizationmicrochip devicedeterminationNi(II)

Як цитувати

Salam Mohammed Nasser, Ahmed Ali Alkarimi, and Dakhil Nassir Tah. Innovative Design and Fabrication of Monolithic Columns Inside Microchip Devices for Determination of Ni(II) Ions. Methods Objects Chem. Anal. 2025, 20(2), 128-134. https://doi.org/10.17721/moca.2025.128-134