ISSN 2413-6166 (Online) · ISSN 1991-0290 (Print) · DOI prefix 10.17721/moca
УкрEn
Відкритий доступ · CC BY 4.0

Development and Validation of a Bioanalytical Method for the Quantification of Clopidogrel in Human Plasma by LC-MS/MS using the Accuracy Profiles

Choukri El Khabbaz, Aimen El Orche, Mustapha Bouatia, Amine Cheikh, My El Abbes Faouzi, Yahia Cherrah, Ratiba Boussen, Houda Bouchafra
#
† Laboratory of Materials Nanotechnologies and Environment, Faculty of Science, Mohammed V University, Rabat, Morocco;
‡ Team of Analytical and Computational Chemistry, Nanotechnology and Environment, Faculty of Science and Techniques, University of Sultan Moulay, Slimane, Beni Mellal-Morocco;
§ Laboratory of Analytical Chemistry, Faculty of Medicine and Pharmacy, Mohammed V University, Rabat, Morocco; ǁ Department of Pharmacy, Faculty of Pharmacy, Abulcasis University, Rabat, Morocco; ₮ Laboratory of Pharmacology and Toxicology, Faculty of Medicine and Pharmacy, Mohammed V University, Rabat, Morocco; # Laboratory of Drug Sciences, Biomedical and Technological Research, Faculty of Medicine and Pharmacy, Hassane II University, Casablanca, Morocco; *e-mail: aimen.elorche@gmail.com

Анотація

A basic bio-analytical method using liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been developed for the determination of clopidogrel in human plasma. Clopidogrel-d3 was used as an internal standard (IS). Protein precipitation with acetonitrile for extraction of clopidogrel and it IS was used. Chromatographic separation of clopidogrel and IS was performed on a Synergi reverse phase C18 column (150 mm × 2 mm, 4 μm) using an isocratic mode. The mobile phase contained a mixture of 0.1% formic acid and acetonitrile (25 : 75) applying a flow rate of 0.4 mL/min. Ionization was performed by an electrospray ionization source (ESI), in positive MRM (Multiple Reaction Monitoring) mode. This method was validated by accuracy profiles approach using tolerance intervals limits. The calibration curve ranged from 0.0156 ng/mL to 8 ng/mL. This method can be employed effectively in bioequivalence and/or pharmacokinetics. In this method we have avoided the use of methanol in all steps of bioanalysis of clopidogrel to avert the back-conversion of clopidogrel metabolite.

Ключові слова:tandem mass spectrometryclopidogrelaccuracy profiles

Як цитувати

Choukri El Khabbaz, Aimen El Orche, Mustapha Bouatia, Amine Cheikh, My El Abbes Faouzi, Yahia Cherrah, Ratiba Boussen, Houda Bouchafra. Development and Validation of a Bioanalytical Method for the Quantification of Clopidogrel in Human Plasma by LC-MS/MS using the Accuracy Profiles. Methods Objects Chem. Anal. 2022, 17(3), 153-161. https://doi.org/10.17721/moca.2022.153-161