ISSN 2413-6166 (Online) · ISSN 1991-0290 (Print) · DOI prefix 10.17721/moca
УкрEn

Evaluation of QuEChERS Sample Preparation for Determination of Benzimidazoles Residues in Meat by UPLC-MS/MS

O.V. Bayer, O.V. Bondarets, V.М. Mykhalska, L.V. Shevchenko, О.М. Stupak, J.V. Fesenko, Y.V. Dovgopol, N.V. Liniichuk, V.L. Kovalenko, I.V. Galka, M. J. Кryvenok, V.M. Poliakovskyi
† State Research Institute for Laboratory Diagnostics and Veterinary and Sanitary Expertise, 30, Donetska Str., Kiev, 02000, Ukraine;
‡ National University of Life and Environmental Sciences of Ukraine, 15 Heroyiv Oborony Str., Kyiv, 03041, Ukraine;
§ Institute of Veterinary Medicine of the NAAS, 30 Donetska Str., Kiev, 03151,Ukraine. *e-mail: mykhalska.vm@gmail.com

Анотація

A liquid chromatographic-tandem mass spectrometric (LC–MS/MS) multi-residue method has been used for the simultaneous quantification and identification of 9 residues and metabolites of benzimidazole derivatives that the most widely used as anthelmintic veterinary drugs of animals. The modified QuEChERS method was used for sample preparation, which was initially developed for pesticide residue analysis. This paper highlights how quick, easy, cheap, effective and rugged the QuEChERS extraction method is. The method was successfully validated according to the 2002/657/EC guidelines. Recovery of analytes was in the range 99 – 110 %. The decission limits (ССα ) were calculated at MRL level for analytes with an established permitted limit as next: 104.5 μg kg-1 (albendazole), 53.2 μg kg-1 (fenbendazole), 54.2 μg kg-1 (flubendazole), 12.1 μg kg-1 (levamisole), 53.9 μg kg-1 (cambendazole), 64.2 μg kg-1 (mebendazole), 52.5 μg kg-1 (parabendazole), 105.8 μg kg-1 (thiabendazole), 234.2 μg kg-1 (triclobendazole). The suitability of the assay has been assessed through InterVal Software by quo data GmbH (Germany). The method achieves high quality of the results, good recovery, repeatabilities, within-lab reproducibilities, and wide analytical scope and has practical benefits, low cost, high sample throughput, little labor used and few lab ware.

Ключові слова:аnthelminticbenzimidazolesresidual contentliquid chromatographymass spectrometrymeat

Як цитувати

O.V. Bayer, O.V. Bondarets, V.М. Mykhalska, L.V. Shevchenko, О.М. Stupak, J.V. Fesenko, Y.V. Dovgopol, N.V. Liniichuk, V.L. Kovalenko, I.V. Galka, M. J. Кryvenok, V.M. Poliakovskyi. Evaluation of QuEChERS Sample Preparation for Determination of Benzimidazoles Residues in Meat by UPLC-MS/MS. Methods Objects Chem. Anal. 2021, 16(1), 32-40. https://doi.org/10.17721/moca.2021.32-40