Indicator films based on gelatin gel for determination of Co(II), Cu(II), Pb(II), Cd(II), Ni(II), Zn(II), Fe(III), Al(III), Ba(II), Sr(II) and SO42-.
Анотація
The commercial photographic films with immobilized metal indicators 4-(2-pyridylazo)resorcinol, nitroso-R-salt, eriochrome cyanine R, alizarin red S, pyrocatechol viole, nitchromazo are recommended to use for the photometric and visual-test determination of Со(II), Cu(II), Pb(II), Cd(II), Ni(II), Zn(II), Fe(ІІІ), Al(III), Ва(II), Sr(II) and SO42-. The optimal conditions for reagent and metal complexes immobilization are founded. The results of microscopic investigations shown that met-al indicators are immobilized only in photo film gelatin layer; the structure and morphology of gelatin layer don’t change after modification. The pH value of isoelectric point of hardened gelatin (4.46 ± 0.04) was determined by the viscometry method. The metrological characteristics for photometric and visual determination using transparent solid-phase reagents were evaluated; the accuracy of the determina-tions was confirmed by independent methods.
Як цитувати
E.A. RESHETNYAK, N.V. IVCHENKO, N.A. NIKITINA, T.B. POCHINOK. Indicator films based on gelatin gel for determination of Co(II), Cu(II), Pb(II), Cd(II), Ni(II), Zn(II), Fe(III), Al(III), Ba(II), Sr(II) and SO42-.. Methods Objects Chem. Anal. 2012, 7(4), 192-201.