Analytical chemistry council

METHODS AND OBJECTS OF CHEMICAL ANALYSIS

 

An international journal devoted to all aspects of analytical chemistry

ISSN 2413-6166 (Online), ISSN 1991-0290 (Print)

Kiev University
    Ukr | En
Home Current issue Call for papers ReceivedContact us
cover

Fabrication of Two Micro Flow Injection Cells and Investigation of the Effect of Flow Cell Volume on Dispersion and Repeatability: A Novel Study

Amal Saadoon Majeed†, Ahmed Saleh Farhood‡*, Rahmah Hashim Abdullah§, Dakhil Nassir TahaII, Nahlah Salman Saddam‡

* Corresponding authors

† Sub-Department of Basic Science, Faculty of Nursing, University of Kufa, Najaf-54003, Iraq;
‡ Department of Chemistry, College of Science, University of Babylon, Hilla-51002, Iraq;
§ Department of Soil and Water, College of Agriculture, Al-Qasim Green University, Babylon-51002, Iraq;
II Al-Mustaqbal University College, Babylon, Hilla- 51002, Iraq;

*e-mail: sci.ahmed.saleh@uobabylon.edu.iq

Methods Objects Chem. Anal., 2024, 19(4), p. 235-240

https://doi.org/10.17721/moca.2024.235-240

The article is distributed under open access Creative Commons Attribution License CC BY 4.0.

download the article

download the references

supplemental materials

Abstract

A new study of the effect of a previously unstudied factor on dispersion, and repeatability of the injected sample. The design idea is based on manufacturing two new microcells with different volumes used in flow injection (FI) analysis systems and determining the measurements of the external structure, internal paths, and the measuring chamber with high accuracy. The efficiency of the FI system was tested by measuring the dead volume, and it was found to be zero. All measurements (n=5) were implemented by using the concentration 10.00 mg/L of Toluidine Blue dye solution at the wavelength 625.0 nm, flow cells with the volumes (35.0, 80.0, and 450.0) μL, sample volumes (39.25 and 78.50) μL, and flow rates (2.6, 4.5, and 6.6) mL/min. The results of the study indicate a relationship between flow cell volume and dispersion values. This relationship becomes apparent when other factors, such as sample volume and flow rate, are changed.

Keywords: homemade micro flow cells, dispersion, repeatability, dead volume, toluidine blue

Article language: En


Publisher: Taras Shevchenko National University, Kiev Ukraine

(Analytical chemistry department at Taras Shevchenko National University, 64 Vladimirskaya STR., Kiev, 01601 UKRAINE)
analysis@univ.kiev.ua, www.univ.kiev.ua, +380 (44) 2393444

The journal is indexed in SCOPUS and Web of Science

The journal website: www.moca.net.ua

The articles in this journal are licensed under CC BY 4.0