Visual Binary Testing of Hydrogen Sulfide Dissolved in Return Underground Local-Water of Oil and Gas Condensate Fields

E.A. Reshetnyak*†, N.N. Nemets‡, O.S. Chernyshova§, A.V. Panteleimonov†, V.M. Ostrovskaya§§

* Corresponding authors
†V.N. Karazin National University, 4 Svoboda Sq., Kharkiv, 61022, Ukraine;
*е-mail: reshetnyak@karazin.ua;
‡Ukraine Research Institute of Nature Gas “UkrNDIgaz”, 20 Gimnazicheskaya naberezhna Str, Kharkiv, 61010, Ukraine;
§SSI "Institute for Single Crystals" NAS of Ukraine, 60 Nauky Ave, Kharkiv, 61072, Ukraine;
§§Federal Autonomous Enterprise "25 State research institute of the Ministry of Defence of Russian Federation", 10 Molodogvardeyskaya Str, Moscow, 121351, Russian Federation

Methods Objects Chem. Anal., 2019, 14(3), p. 146-152

https://doi.org/10.17721/moca.2019.146-152

Buy Article:

5 USD plus tax

DOI Id

preview the article

download the references

Abstract

In order to screen samples of return underground local-water of oil and gas condensate fields for the presence of dissolved hydrogen sulfide, it was proposed to use single comparison sample for visual binary testing of H2S. Two indicator reactions occurring in solutions were selected — the formation of a stabilized suspension of MnS and CdS. Suspensions prepared in the presence of borate buffer (pH 9.18) and gelatin (stabilizer) are stable during the twenty four hours; a difference in the turbidity of suspensions can be observed near the normalized concentration of hydrogen sulfide (сlim = 15 mg L-1). When establishing the concentration of H2S in the comparison samples, a statistical approach was applied; the estimated values of the threshold concentration of H2S (ccomp.) are less than the normalized level on the value which providing the risk of a false-negative test result not more than 5% - 11.6 mg L-1 for MnS and 13.4 mg L-1 for CdS. Preference was given to a test system based on a stabilized suspension of CdS, because for this reaction, a narrower interval of unreliability and the value of ccomp. is nearer to the value of the сlim. The correctness of the visual binary testing of H2S in the samples of the analyzed water was confirmed by spectrophotometric method with p-phenylenediamine.

Keywords: hydrogen sulfide, oil and gas condensate fields, return underground local-water, visual binary testing, stabilized suspension, spectrophotometry, p-phenylenediamine

Article language: Rus


Publisher:Taras Shevchenko National University, Kiev Ukraine

(Analytical chemistry department at Taras Shevchenko National University, 64 Vladimirskaya STR., Kiev, 01601 UKRAINE)
analysis@univ.kiev.ua, www.univ.kiev.ua, +380-44-2393266

The journal is indexed in SCOPUS and Web of Science

The journal website: www.moca.net.ua

The articles in this journal are licensed under CC BY 4.0