Analytical chemistry council

METHODS AND OBJECTS OF CHEMICAL ANALYSIS

ISSN title: "Metody i obʺekty himičeskogo analiza"

An international journal devoted to all aspects of Analytical chemistry

ISSN 2413-6166 (Online), ISSN 1991-0290 (Print)

Kiev University
  Ukr | En
Home  Call for papers ReceivedContact us
cover

Study of Interaction of some Benzodiazepines with Human Serum Albumin by Fluorescent Method

A.V. Yegorova*†, G.V. Maltsev‡, Y. V. Scrypynets†, S.N. Kashutskуy‡, V. P. Antonovich†

* Corresponding authors
† A.V. Bogatsky Physico-chemical Institute of the National Academy of Sciences of Ukraine, Lustdorfskaya doroga, 86, 65080, Odessa, Ukraine;
*e-mail: yegorova@interchem.com.ua
‡ "INTERCHEM SLC", Lustdorfskaya doroga, 86, 65080, Odessa, Ukraine;

Methods Objects Chem. Anal., 2018, 13(1), p. 18-28

https://doi.org/10.17721/moca.2018.18-28

Buy Article:

2 USD plus tax

DOI Id

preview the article

Abstract

Fluorescence spectroscopy is one of the most effective methods for studying intermolecular interactions that reflect the change in the environment of a fluorophore. It helps to establish the binding of small molecules (drugs) to proteins. In the model physiological conditions, the interaction between certain benzodiazepines (BD) and human serum albumin (HSA) by fluorescence in combination with the method of ultraviolet spectroscopy was studied. The results of the experiment shows that the BD quench the intrinsic fluorescence of protein as a result of static interaction in the HSA - BD systems, which is confirmed by the shifts in the difference UV spectra of the HSA - BD and the reduction of binding constants for the HSA - BD systems with increasing temperature. The interaction parameters, such as the binding constant (KA), enthalpy change (ΔHº) and entropy change (ΔSº) were determined. The average distance (r) between DZP and tryptophan residue of HSA was calculated using theory of resonance energy transfer. It is established that the average distance between donor and acceptor molecules for HSA - BD systems is from 1.32 nm to 1.79 nm. Synchronous fluorescence spectra of BD at Δλ = 60 nm shows a bathochromic shift (from 3 nm to 6 nm), which indicates the presence of conformation changes of protein near the tryptophan residue.

Keywords: human serum albumin, fluorescence, benzodiazepines

Article language: Rus

ReferencesPreview
 

Publisher:Taras Shevchenko National University, Kiev Ukraine

(Analytical chemistry department at Taras Shevchenko National University, 64 Vladimirskaya STR., Kiev, 01601 UKRAINE)
analysis@univ.kiev.ua, www.univ.kiev.ua, +380-44-2393266

The journal is indexed in SCOPUS and Web of Science

The journal website: www.moca.net.ua

The articles in this journal are licensed under CC BY 4.0