LC–MS/MS Profiling of Stress-Induced Degradation Products of Avapritinib and Development of a Stability-Indicating HPLC Method for Its Quantification and Impurity Analysis
† Department of Inorganic and Analytical chemistry, Andhra University, Visakhapatnam-530003, AP, India;
‡ Department of Biotechnology, Karunya Institute of Technology and Sciences (Deemed University), Karunya Nagar, Coimbatore-641114, Tamil Nadu, India;
§ Department of Chemistry, Andhra University, Andhra University, Visakhapatnam - 530003, Andhra Pradesh, India; II Dr. Samuel George Institute of Pharmaceutical and Technology, Markapur - 523316, Andhra Pradesh, India; ┴ Dept. of Inorganic and Analytical Chemistry, Andhra University, Visakhapatnam-530003, AP, India; # CEO-QDOT Associates (former VP & Head of CQC, ASAT & EMQA at Dr. Reddy’s Laboratories Limited, Hyderabad, India *e-mail: rasheedbabu.sk@gmail.com
Abstract
The stability and purity of pharmaceutical compounds are critical for ensuring drug efficacy and patient safety. Avapritinib, a tyrosine kinase inhibitor used to treat gastrointestinal stromal tumors and other cancers, requires a robust analytical method for its quantification and stability assessment. This study presents a validated stability-indicating high-performance liquid chromatography (HPLC) method for the separation, identification, and quantification of avapritinib and its impurities under various stress conditions. The method utilizes an X-Bridge C18 (250 mm × 4.6 mm, 5 μm) column with a mobile phase composed of acetonitrile and a methanol–phosphate buffer mixture (pH 3.6, 0.01M) in a 70:30 v/v ratio, employing a linear gradient elution at 0.9 mL/min with UV detection at 251 nm. The method exhibited high selectivity and resolution (Rs > 2), excellent linearity (r² > 0.999) within 25–150 μg/mL for avapritinib and 0.25–1.5 μg/mL for its impurities, and precision with RSD% below 2%. Recovery studies confirmed accuracy (99.58% for avapritinib, 99.72–100.17% for impurities). Forced degradation studies identified significant degradation under acidic and photolytic conditions, leading to the formation of distinct degradation products (ADP 1, ADP 2, PDP 1, PDP 2, and PDP 3). Structural elucidation via mass spectrometry revealed degradation pathways, with ADP products forming under acidic conditions and PDP products under photolytic stress. The developed method provides a reliable tool for avapritinib quantification and stability assessment, offering critical insights into its degradation behavior for improved therapeutic safety and efficacy.
How to cite
Rasheed Babu Shaik, Sasi Kumar Reddy Padala, D. Samsonu, Dharmasoth Rama Devi, K. Basavaiah, B.M. Rao. LC–MS/MS Profiling of Stress-Induced Degradation Products of Avapritinib and Development of a Stability-Indicating HPLC Method for Its Quantification and Impurity Analysis. Methods Objects Chem. Anal. 2025, 20(1), 52-58. https://doi.org/10.17721/moca.2025.52-58